Series 261 Structural Pressure Test Controller (SPTC)
Achieve precise control of pressurized airflow throughout demanding cyclic pressurization tests of aircraft and spacecraft cabins and structural components. Easy to setup and operate, Series 261 units integrate seamlessly with AeroPro software and FlexTest controllers to deliver reliable, accurate and repeatable closed-loop pressure control that can be synchronized with other structural test loading.
Works in concert with pressurized air supply and a system controller to deliver tight, closed-loop pressure control
Integrated / Synchronized
Integrates seamlessly with the complete MTS portfolio of aerospace structural test solutions
Easy, Intuitive Use
Features intuitive front panel and provides easy test configuration and setup
Efficient Operation
Over-pressure circuit mitigates potential damage from excessive structure pressure
Technical Overview
261.01
261.04
261.08
Maximum supply pressure
0.83 MPa (120 psi)
0.83 MPa (120 psi)
0.83 MPa (120 psi)
Maximum structure pressure*
0.69 MPa (100 psi)
0.69 MPa (100 psi)
0.69 MPa (100 psi)
Pressure Accuracy*
<0.4% full scale
<0.7% full scale
<0.7% full scale
Maximum flow capacity
0.283 m3/s at 0.83 MPa
(600 scfm at 120 psi)
3.633 m3/s at 0.83 MPa
(7700 scfm at 120 psi)
7.268 m3/s at 0.83 MPa
(15400 scfm at 120 psi)
Hose diameters:
Supply
76.2 mm (3 in)
76.2 mm (3 in)
152 mm (6 in)
Structure
76.2 mm (3 in)
152 mm (6 in)
265 mm (10 in)
Exhaust
76.2 mm (3 in)
152 mm (6 in)
265 mm (10 in)
System controller outputs:
Solenoid valves
1.5 A at 24 V DC
1.5 A at 24 V DC
1.5 A at 24 V DC
Pressure control command signal
0 to 10 V DC
0 to 10 V DC
0 to 10 V DC
Maximum ambient operating temperature
65°C (150°F)
65°C (150°F)
65°C (150°F)
Minimum ambient operating temperature
0°C (32°F)
0°C (32°F)
0°C (32°F)
Dimensions:
Height
578 mm (22.8 in)
2096 mm (82.5 in)
2096 mm (82.5 in)
Depth
712 mm (28 in)
1008 mm (39.7 in)
1008 mm (39.7 in)
Width
762 mm (30 in)
800 mm (31.5 in)
800 mm (31.5 in)
* The maximum structure pressure specified is the maximum designed level for the SPTC in the local mode. For a maximum structure pressure less than 0.69 MPa (100 psi), the required maximum structure pressure must be specified at the time of order.
† The pressure accuracy rating depends on the calibrated range of the proportional valve and the accuracy of the external feedback device.
Specifications are subject to change without notice.
Ready for a quote or need more information? We're here to help.
Request a quote
We use necessary cookies to make our site work. We'd also like to set up optional analytics cookies to help us improve it. We won't set optional cookies unless you enable them.
We use necessary cookies to make our site work. We'd also like to set up optional analytics cookies to help us improve it. We won't set optional cookies unless you enable them.