The TMF Subsystem is ideal for inducing thermal cycling in a metallic (magnetically susceptible) specimen. A combination of induction heating and air cooling allows thermomechanical fatigue tests to be performed in or out of phase with a load force. The TMF subsystem has a user-friendly design that helps operators perform repeatable test setup tasks quickly.
Highly accurate and repeatable TMF testing at temperatures up to 1200°C
Pre-Configured Software
TestSuite™ software templates to test to ASTM E2368, ISO 12111 and the European Validated Code of Practice for Strain-Controlled Thermomechanical Fatigue Testing
Easy Setup
Designed for streamlined repeatable testing
Accurate & Repeatable
Air-cooling jets and the induction coil easily reset to original position after changing specimen
Featured Case Studies
Rolls-Royce - thermomechanical fatigue testing of aircraft engine components
The TMF Subsystem is ideal for inducing thermal cycling in a metallic (magnetically susceptible) specimen. A combination of induction heating and air cooling allows thermomechanical fatigue tests to be performed in or out of phase with a load force. The TMF subsystem has a user-friendly design that helps operators perform repeatable test setup tasks quickly. Air cooling jets and the induction coil have easy, repeatable adjustments, meaning that specimen changes do not require as much setup time to reestablish the initial conditions. A specimen centering tool provides quick initial position for the coil. The coil is mounted on an x, y, z positioner that has manual adjustment knobs with numerical indicators allowing 50 mm of travel in 3-axes for fine positioning relative to the specimen. A quick release slide allows the coil to be easily pulled from the test space with the ability to return to its original position. Air cooling jets are also easily folded back or removed to gain access to the specimen with the same ability to snap back into the original position.
The induction coil is coated in electrically insulating material to provide an additional safety factor against electric shock. The coil, generator and RF oscillator are water cooled and interlocked for water flow. A second interlock specimen thermocouple also provides indication in the event that the primary control thermocouple becomes detached. TestSuite software templates for TMF include test setup, to establish thermal gradients; and test run, to perform and report results on the TMF test.
10 kW RF Generator with temperature controller and secondary temperature interlock controller
Air-cooling jets with detachable arms and adjustable flow profiles
10°C/second heating and cooling with higher open loop heating rates possible
Temperature range up to 1200°C
X,Y,Z coil with position indication and quick release slide-back mount
Type K or Type R thermocouple compatibility
Water chiller for RF generator and coil
Tool kit for coil centering and adjustment
Standard 5-turn electrically insulated induction coil
TestSuite software templates for setup and test control
Instrumented specimen for equipment checkout and validation
16 channel thermocouple data acquisition module
Thermocouple connector kit to interface with specimen
Designed to accommodate MTS high-temperature axial extensometers
When ordering, please indicate power choice of water chiller 50 Hz or 60 Hz), thermocouple type (R or K).
Maximum Specimen Temperature
1200°C (2192°F)
Typical Heating Rate*
10°C/s (18°F/s)
Typical Cooling Rate*
5°C/s (9°F/s)
Standard Coil Geometry
Custom coils available upon request
» 50 mm (2 in) tall coil with 5 tapered spiral turns
» Includes internal water cooling
Standard Specimen Types
Round
Hollow
Option for internal cooling of hollow specimens**
Standard Specimen Geometry
Minimum Length: 125 mm (5 in)
Diameter: 6 to 12 mm (0.25 to 0.5 in)
RF Generator Power
10 kW
RF Generator Frequency Range
50 to 200 kHz at 10 kVA
Thermocouple Type
K (R optional)
Temperature Control and Interlocks
Two temperature controllers with safety interlocking
» One provides control
» One is for over-temperature
Number of Temperature Monitoring Channels
Up to 16
Coil Adjustment: Maximum Travel of x, y, z Positioner
50 mm (2 in)
Certification
CE/NRTL
*Dependent on specimen material, specimen geometry, and required temperature range.